AQ-F205 Feeder protection device
AQ-F205_web_v3
AQ-F205_web_v3

Description

The AQ-F205 feeder protection device is suitable for any application that requires directional overcurrent and earth fault protections along with voltage and frequency protections. The AQ-F205 feeder protection device comes with complimentary measurement, monitoring, control and communication features. The relay’s standard configuration of eleven (11) digital inputs and ten (10) digital outputs along with a large, programmable HMI allow for a variety of adaptations.

Highlights:

  • Integrated protection, control, and measurement.
  • Price–performance ratio.
AQ-F205_web_v3

Technical data

  • Non-directional overcurrent (I>; 50/51) - 4 stages (INST, DT or IDMT)
  • Non-directional earth fault (I0>; 50N/51N) - 4 stages (INST, DT or IDMT)
  • Directional overcurrent (Idir>; 67) - 4 stages (INST, DT or IDMT)
  • Directional earth fault (I0dir>; 67N/32N) - 4 stages (INST, DT or IDMT)
  • Negative sequence overcurrent/ Phase current reversal/ Current unbalance (I2>; 46/46R/46L) - 4 stages (INST, DT or IDMT)
  • Harmonic overcurrent (Ih>; 50H/51H/68H) - 4 stages (INST, DT or IDMT)
  • Circuit breaker failure protection (CBFP; 50BF/52BF)
  • High-impedance or low-impedance restricted earth fault/ Cable end differential (I0d>; 87N)
  • Overvoltage (U>; 59) - 4 stages (INST, DT or IDMT)
  • Undervoltage (U<; 27) - 4 stages (INST, DT or IDMT)
  • Neutral overvoltage (U0>; 59N) - 4 stages (INST, DT or IDMT)
  • Sequence voltage (U1/U2>/<; 47/27P/59PN) - 4 stages (INST, DT or IDMT)
  • Overfrequency and underfrequency (f>/<; 81O/81U) - 8 stages (INST or DT)
  • Rate-of-change of frequency (df/dt>/<; 81R) - 8 stages (INST, DT or IDMT)
  • Overpower (P>; 32O)
  • Underpower (P<; 32U)
  • Reverse power (Pr; 32R)
  • Line thermal overload (TF>; 49F)
  • Voltage memory

  • Number of objects to control and monitor: 5
  • Number of indicators to monitor: 5
  • Number of setting groups: 8
  • Cold load pick-up
  • Switch-on-to-fault
  • Auto-recloser (0 → 1; 79)
  • Synchrocheck (ΔV/Δa/Δf; 25)

  • Phase, sequence and residual currents (IL1, IL2, IL3, I01, I02)
  • Phase, sequence and residual voltages (UL1, UL2, UL3, U12, U23, U31, U0)
  • Frequency (f)
  • Power (P, Q, S, pf) and Energy (E+, E-, Eq+, Eq-)
  • Power and energy class 0.5
  • Current transformer supervision
  • Voltage transformer supervision (60)
  • Circuit breaker wear monitoring
  • Total harmonic distortion (current)
  • Total harmonic distortion (voltage)
  • Fault locator (21FL)
  • Measurement recorder
  • Measurement value recorder
  • Event recorder (max. 15 000 permanent event records)
  • Disturbance recorder (max. 100 records á 5 seconds at 3.2 kHz sampling)

  • Current inputs: 5
  • Voltage inputs: 4
  • Digital inputs (fixed): 11
  • Digital outputs (fixed): 10

  • Communication inputs
  • RJ-45 100 Mbps Ethernet (front panel, fixed)
  • RJ-45 100 Mbps Ethernet and RS-485 (rear panel, fixed)
  • Communication protocols
  • IEC 60870-5-101/104
  • IEC 60870-5-103
  • Modbus/RTU and Modbus/TCP
  • DNP3
  • SPA

  • AX009 Raising frame (87 mm)
  • AX010 Raising frame (40 mm)
  • AX011 Combiflex frame
  • AX012 Wall mounting bracket

Additional material

Application Drawing

An application image for AQ-F205 feeder protection device, with one version drawn according to IEC standard symbols and the other according to IEEE/ANSI standard symbols.

Device Rear Image

Device rear image_AQ-205

Device and Cut-out Image

AQ-210 dimensions and cut-out

Order Code

Order code_F205

Related products

AQ-F213_web_cropped

AQ-F213 Feeder protection devices

The AQ-F213 feeder protection devices provide optimal performance for medium-voltage (main) or high-voltage (back-up) protection, control, […]

AQ-F213a_web_v3

AQ-F213A Feeder protection device

The AQ-F213A feeder protection device provides optimal performance for medium-voltage (main) or high-voltage (back-up) protection, control […]