AQ-F255R Feeder protection device
AQ-F255R_web
AQ-F255R_web

Description

The AQ-F255R feeder protection device offers a modular recloser control solution for applications that require a large I/O capacity. You can add up to eleven (11) I/O or communication modules into the device for extensive monitoring and control applications. AQ-F255R has a special object which allows for phase-specific tripping and recloser control. The AQ-F255R feeder protection device communicates using various protocols, including the IEC 61850 substation communication standard.

Highlights:

  • A large I/O capacity.
  • A special object for phase-specific tripping and recloser control.
  • Power and energy measurement accuracy of up to 0.2 %.

See all AQ-F255 variants

AQ-F255R_web

Technical data

  • Non-directional overcurrent (I>; 50/51) - 4 stages (INST, DT or IDMT)
  • Non-directional earth fault (I0>; 50N/51N) - 4 stages (INST, DT or IDMT)
  • Single-pole non-directional overcurrent protection (IPW>; 50/51) – 2 stages (DT or IDMT)
  • Directional overcurrent (Idir>; 67) - 4 stages (INST, DT or IDMT)
  • Directional earth fault (I0dir>; 67N/32N) - 4 stages (INST, DT or IDMT)
  • Intermittent earth fault (I0int>; 67NT)
  • Negative sequence overcurrent/ Phase current reversal/ Current unbalance (I2>; 46/46R/46L) - 4 stages (INST, DT or IDMT)
  • Harmonic overcurrent (Ih>; 50H/51H/68H) - 4 stages (INST, DT or IDMT)
  • Circuit breaker failure protection (CBFP; 50BF/52BF)
  • High-impedance or low-impedance restricted earth fault/ Cable end differential (I0d>; 87N)
  • Overvoltage (U>; 59) - 4 stages (INST, DT or IDMT)
  • Undervoltage (U<; 27) - 4 stages (INST, DT or IDMT)
  • Neutral overvoltage (U0>; 59N) - 4 stages (INST, DT or IDMT)
  • Sequence voltage (U1/U2>/<; 47/27P/59PN) - 4 stages (INST, DT or IDMT)
  • Overpower (P>; 32O)
  • Underpower (P<; 32U)
  • Reverse power (Pr; 32R)
  • Overfrequency and underfrequency (f>/<; 81O/81U) - 8 stages (INST or DT)
  • Rate-of-change of frequency (df/dt>/<; 81R) - 8 stages (INST, DT or IDMT)
  • Line thermal overload (TF>; 49F)
  • Resistance temperature detectors (RTD)
  • Voltage memory
  • Programmable stage (PGx>/<; 99)
  • Arc protection (IArc>/I0Arc>; 50Arc/50NArc) (optional)

  • Number of objects to control and monitor: 10
  • Single-pole object control and monitoring
  • Number of indicators to monitor: 10
  • Number of setting groups: 8
  • Cold load pick-up
  • Switch-on-to-fault
  • Auto-recloser (0 → 1; 79)
  • Zero sequence recloser
  • Vector jump (Δφ; 78)
  • Synchrocheck (ΔV/Δa/Δf; 25)

  • Phase, sequence and residual currents (IL1, IL2, IL3, I01, I02)
  • Phase, sequence and residual voltages (UL1, UL2, UL3, U12, U23, U31, U0)
  • Frequency (f)
  • Power (P, Q, S, pf) and Energy (E+, E-, Eq+, Eq-)
  • Power and energy class 0.5
  • Power and energy measurement accuracy of up to 0.2 % (optional)
  • Current transformer supervision
  • Voltage transformer supervision (60)
  • Circuit breaker wear monitoring
  • Total harmonic distortion (current)
  • Total harmonic distortion (voltage)
  • Fault locator (21FL)
  • Measurement recorder
  • Measurement value recorder
  • Event recorder (max. 15 000 permanent event records)
  • Disturbance recorder (max. 100 records á 5 seconds at 3.2 kHz sampling)

  • Current inputs: 5
  • Voltage inputs: 4
  • Digital inputs (fixed): 3
  • Digital outputs (fixed): 5
  • Number of empty slots: 11
  • Digital inputs: +8/16/24/32/40/48/56/64/72/80/88 (optional)
  • Digital outputs: +5/10/15/20/25/30 (optional)
  • Milliampere I/O module (4 mA outputs + 1 mA input)
  • Arc protection module (4 sensors + 2 HSO + 1 BI)
  • Communication media (see "Communication" below)
  • External I/O modules (see "Accessories" below)

  • Communication inputs
  • RJ-45 100 Mbps Ethernet (front panel, fixed)
  • RJ-45 100 Mbps Ethernet and RS-485 (rear panel, fixed)
  • 2 x RJ-45 100 Mbps Ethernet with an IRIG-B input (optional)
  • 2 x ST 100 Mbps Ethernet with an IRIG-B input (optional)
  • 2 x LC 100 Mbps Ethernet (PRP/HSR) (optional)
  • RS-232 serial fiber (PP/PG/GP/GG) (optional)
  • Communication protocols
  • IEC 61850 (edition 1)
  • IEC 61850 (edition 2)
  • IEC 60870-5-101/104
  • IEC 60870-5-103
  • Modbus/RTU and Modbus/TCP
  • DNP3
  • SPA

  • AX007 External 6-channel 2-/3-wire RTD input module (pre-configured)
  • AX008 External 8-channel thermocouple and mA input module (pre-configured)
  • AX013 Raising frame (120 mm)
  • AX014 Raising frame (40 mm)
  • AX015 Wall mounting bracket

Additional material

Application Drawing

An application image for AQ-F255R feeder protection device with single-pole non-directional overcurrent protection and single-pole object control and monitoring, with one version drawn according to IEC standard symbols and the other according to IEEE/ANSI standard symbols.

Device Rear Image

Device rear image_AQ-255-AAAAAAAAA

Device and Cut-out Image

AQ-250 dimensions and cut-out

Order Code

Order code_F255x (A,R,S)